Energy Storage System
Creating a Reliable and Sustainable Energy Environment with Renewable Energy and Storage Systems
Since its establishment in 1965, Klacci Technology Co., Ltd.(a subsidiary of I-TEK Enterprise) has been known for supplying intelligent access control systems. Guided by the mission to “make everyone’s life safer and their property more secure,”Klacci is committed to providing innovative, secure, and convenient solutions.Beyond its expertise in intelligent access control systems, Klacci integrates NFC, Bluetooth, and RFID technologies to create efficient mobile access and biometric solutions tailored for high-end residential and commercial office needs. Its smart building solutions combine automated door controls with contactless technology, offering a healthy and convenient lifestyle in the post-pandemic era.
Klacci embeds environmental sustainability into its core values. Through advanced energy-saving technologies, the company introduces secure energy storage systems to meet high-energy demands. These systems provide multiple benefits, including peak shaving, backup power supply, and carbon emission reduction. They enable customers to flexibly manage electricity usage, precisely control energy costs, optimize energy efficiency, and reduce environmental impact.
With stringent quality management and over 100 patents, Klacci’s products have earned ANSI and UL certifications and are marketed globally, deployed across diverse sectors such as government institutions, schools, and hospitals. Driven by continuous technological innovation, Klacci integrates safety and energy-saving features into smart buildings, creating a safer and more sustainable living environment, delivering profound value to customers and society.
We prioritize an environmentally friendly, stable, and easily maintainable safe usage environment, protecting the planet while providing reliable and efficient energy support.

System Advantages
Safety
Value
Intelligent Maintenance
The system has been certified and a patent application has been filed
- UL 9540A Energy storage system thermal runaway propagation assessment test
- UL 1973 Standard for Batteries
- IEC 62619 Safety testing for industrial applications of secondary lithium-ion battery packs
- CE-EMC Electromagnetic compatibility testing
- UN 38.3 Testing the safety of lithium batteries in air transport


System Application


System Configuration
The system architecture converts electricity generated from solar energy through a Power Conditioning System (PCS), enabling storage in battery modules or direct supply to loads. The Energy Management System (EMS) oversees real-time monitoring, data analysis, and equipment scheduling. Through automated management, it effectively enhances the utilization rate of renewable energy, while reducing energy consumption and mitigating the issue of high power generation costs.
System Feature Evaluation
Klacci’s energy storage is not just a backup, but an active defense and value enhancement, the system features
- High Safety: No fire, no explosion, no overheating
- Intelligent Adjustment: Store electricity at low prices, discharge at high prices
- Structural Stability: Reduces battery temperature and remains reliable under long-term loads
- Highly durable: Long lifespan and low maintenance
- Easy to operate: No dedicated personnel required; easy to manage
| Klacci | Other manufacturers | |
|---|---|---|
| Feature Comparison | Low-Voltage Battery Parallel Connection System | High-Voltage Battery Series Connection System |
| Operating temperature | Low | High (Endpoint) |
| BMS Battery Module Control System | Low (On / Off)Automatic Balancing | High (Overcharge Monitoring/Overdischarge) |
| Cooling System | Working Temperature: 40 ± 5°C (Natural Cooling with Exhaust Fan) | High Temperature Above 80°C (Needs forced air / liquid / immersion cooling) |
| Charging and Discharging (SOC) | 90% | 80% |
| Battery Remaining Capacity after 5 Years | >90% | <80% |
| Auxiliary System Energy Consumption | Low | High |
| Safety | Ensures safety for both personnel and products | Risks include high-temperature and high-voltage runaway, as well as electric shock hazards to personnel |
| Risk of Electric Shock to Personnel | No Risk of Electric Shock (Low Voltage) Arc voltage below 60V Gasification occurs below 900V | High risk of electric shock (Requires high-voltage insulation) Arc voltage above 900V Vaporization above 1100V |
| Fire Risk Safety | Extremely Safe | Danger |
| Initial Setup Cost | High | Low |
| Operation and Maintenance Cost | Low (Easy to replace) Can be handled anytime by a general electrician | High (Difficult to replace) Needs upkeep from skilled electrical technicians |
| Reliability Rate | 99.99% availability with no downtime Supports hot-swappable maintenance Longer battery life | Cabinet shutdown with 3 charge-discharge cycles Requires at least 2 days for battery equalization Requires at least 15 days of annual downtime |
| Placement / Installation area | Indoor/outdoor use allowed | Limited to outdoor, enclosed spaces |
| Required Space (Area Efficiency) | 20′ container (1.1M) | 20′ container (2.4M) |
Klacci Low-voltage Parallel
No air conditioning required – natural heat dissipation design saves energy. Ideal for applications with high safety requirements.

Other manufacturers High-voltage Connection
Additional cooling, such as air conditioning or liquid cooling, is needed to ensure system stability.


EMS System Management

This EMS (Energy Management System) is centered around the NextDrive Smart Energy Gateway, which connects all on-site electricity consumption, power generation, and energy storage equipment. Through the NextDrive Cloud platform, data is uploaded to the cloud for centralized management.
The web-based EMS interface allows administrators to monitor and manage energy systems in real time.
Optional Fire Suppression System
This energy storage system combines the electrochemical characteristics of the battery with a self-developed intelligent power controller to effectively solve the voltage matching issue between low-voltage batteries and high-voltage PCS, while simplifying the control system and enhancing safety and performance. Utilizing EDC (Efficient Data Collection and Distributed Control System) technology, combined with thermocouple modules and DIDO control modules, the system can precisely monitor temperature variations within the energy storage cabinet batteries and detect anomalies in real time to ensure safety.
EDC Automatic Fire Extinguishing Function
- The system can be optionally equipped with an automatic fire suppression system. When an abnormal condition is detected, it will automatically activate alarms, cut off power, or release extinguishing agents targeting the thermal runaway cells, extinguishing the fire immediately. This effectively prevents fire escalation and ensures safety.
- This system uses an environmentally friendly, plant-based, non-toxic fire extinguishing agent that can extinguish Class A fires and lithium battery fires. The agent is biodegradable in soil or can be recycled, making it environmentally friendly.


Thermal Runaway Cause Analysis of Competing Systems
The Other Manufacturers’ Systems waterproof design limited the fire suppressant to the outer casing, failing to extinguish burning lithium cells inside. Gas agents cannot put out Class A fires, leading to uncontrolled fire spread.
Specifications
125kW

| Battery Cabinet Performance Parameters | |
|---|---|
| Number of Routes | 1 |
| DC Voltage Range | 600 – 1000Vdc |
| Maximum DC Current | 198A |
| Rated DC Power | 125kW |
| Stabilizing Accuracy | ≤±2% |
| Stabilization Accuracy | ≤±5% |
| Pressure Limiting Characteristics | Eligible |
| Current Limiting Characteristics | Eligible |
| AC Output (Grid) | |
| Rated Output Power | 125kW |
| Overload Capacity | 1.1x Long Term |
| Rated Voltage | AC400V |
| Rated Output Current | 180A |
| AC Access Method | Three-Phase Four-Wire |
| Isolation | Non-Isolated |
| Grid Voltage Range | 400V (-15% – +15%) |
| Grid Frequency Range | 50Hz / 60Hz±2.5Hz |
| Total Harmonic Distortion Rate | ≤3% (Fully Loaded) |
| Power Factor | 0.99 / -1 – 1 |
| Current DC Component | ≤0.5% |
| Charge/Discharge Conversion Time | <100ms |
| Size (W×H×D) | 800 × 1800 × 800mm |
| AC Output (Load) | |
| AC Off-Grid Voltage | 400Vac |
| AC Voltage Range | 400Vac±3% |
| AC Off-Grid Frequency | 50Hz / 60Hz |
| Offline Output THDU | ≤3% (Linear load) |
| Unbalanced Load Capability | 1 |
| Offline Multi-Computer Parallel Connection | Nonsupport |
| DC Side Parallel Connection | Nonsupport |
| General Specifications | |
| Dimensions (W×H×D) | 520 × 240 × 680mm |
| Weight | 70 kg |
| Cooling Method | Compulsory Air-Cooled |
| Maximum Working Altitude | 3000m |
| Operating Temperature Range | -20°C – 60°C |
| Allowable Relative Humidity | ≤95% |
| Protocol | BMS-CAN | EMS -Network Port / RS485 |
| Maximum Conversion Efficiency | ≥99% |
| Newsletter | ≤75dB |
| Multi-Module Networking | DC Side Separate – AC Side Parallel Connection |
| Waterproof Rating | IP21 Indoor Container |
110kWh

| Performance Parameters | |
|---|---|
| Voltage Output Range | 500 – 850Vdc (Constant Voltage Adjustable) |
| Max. Discharge Power | 100kW |
| Max. Output Current | 150A |
| Max. Charging Power | 100kW |
| Total Energy | 220kWh |
| Battery Module Specification | 51.2V 100Ah |
| Battery Module Number | 22 |
| General Specifications | |
| Dimensions (W×H×D) | 800 × 1900 × 1200mm |
| Weight | 1600 kg |
| Cooling Method | Natural Cooling |
| Operating temperature | Charging: 0°C – 56°C Discharging: -20°C – 56°C |
| Waterproof Rating | IP21 Indoor Container / IP65 Outdoor Container |
| Protocol | CAN / RS485 |
| Cycle Life | ≥6000 times |
208kWh

| Performance Parameters | |
|---|---|
| Voltage Output Range | 600 – 850Vdc (Constant Voltage Adjustable) |
| Max. Discharge Power | 104kW |
| Max. Output Current | 140A |
| Max. Charging Power | 104kW |
| Total Energy | 208kWh |
| Battery Module Specification | 51.2V 100Ah |
| Battery Module Number | 13 |
| General Specifications | |
| Dimensions (W×H×D) | 1000 × 1950 × 1250mm |
| Weight | 1750 kg |
| Cooling Method | Forced Air Cooling |
| Operating temperature | Charging: 0°C – 56°C Discharging: -20°C – 56°C |
| Waterproof Rating | IP21 Indoor Container |
| Protocol | CAN / RS485 |
| Cycle Life | ≥6000 times |
6.5kW Hybrid Inverter

- Supports Parallel Connection
- Can connect up to 6 units in parallel (Exceeding the quantity may cause delays in RS485 communication function.)
| Performance Parameters | |
|---|---|
| Phase | Single-phase Input / Single-phase Output |
| Max. PV Input Power | 6500W |
| Rated Output Power | 6000W |
| Max. Charging Power | 6000W |
| Parallel Capability | Able to Connect 6 Units in Parallel |
| Photovoltaic Input (DC) | |
| Rated DC Voltage / Maximum DC Voltage | 360Vdc / 500Vdc |
| Starting Voltage / Initial Supply Voltage | 60V / 90Vdc |
| Maximum Power Voltage Range | 60Vdc – 450Vdc |
| Maximum Input Current | 1/20A |
| Maximum Conversion Efficiency (DC/AC) | >99% |
| Grid Input (AC) | |
| Nominal Voltage (AC) | 220 / 230 / 240VAC |
| Output Voltage Range | 170 – 264 VAC / 90 – 264 VAC |
| Rated Output Current | 24A |
| Power Factor | >0.99 |
| Total Harmonic Distortion (THD) | <3% |
| Conversion Efficiency | |
| Maximum Conversion Efficiency (DC/AC) | 93% (Battery DC/AC) 97% (PV DC/AC) |
| Off-grid and Hybrid Operation | |
| AC Startup Voltage / Automatic Restart Voltage | 170 / 180VAC |
| Frequency Range | 45 – 65Hz |
| Acceptable Input Voltage Range | 170 – 264 VAC / 90 – 264 VAC |
| Maximum AC Input Current | 30A |
| Battery Output | |
| Nominal Output Voltage | ≤0.5% |
| Rated Output Power | <100ms |
| Pulse Power | 800 × 1800 × 800mm |
| Switch Time | <10ms |
| Output Waveform | Pure sine wave |
| Total Harmonic Distortion (THD) | <3% |
| Efficiency (DC/AC) | 92% |
| Batteries and Charging | |
| Rated DC Voltage | 48Vdc |
| Maximum Solar Charging Current | 100A |
| Maximum AC Charging Current | 80A |
| Max. Charging Current | 100A |
| General Specifications | |
| Dimensions (W×H×D) | 260 × 450 × 102mm |
| Weight | 8.5 kg |
| Protocol | RS485 / Wi-Fi / GPRS / Lithium Battery |
| Relative Humidity | 0 – 90% |
| Operating temperature | -10°C – 50°C |
5kWh Battery Module (3U)

| Battery Module Performance Parameters | |
|---|---|
| Rated Voltage | 51.2Vdc |
| Output Voltage Range | 44.8-57.6Vdc |
| Nominal Capacity | 100Ah |
| Rated Energy | 5.12kWh |
| Rated Discharge Current | 50A |
| Max. Discharge Current | 100A |
| Rated Charge Current | 50A |
| Max. Charging Current | 100A |
| Max. Discharge Power | 5.12kW |
| Max. Charging Power | 4kW |
| Performance | ≥95% DOD |
| Voltage Sampling Quantity | 16S |
| Battery Balancing | Active Balancing 3A |
| Dimensions (W×H×D) | 484 × 133 × 470mm |
| Weight | 40±1 kg |
| Operating temperature | Charging: 0°C – 45°C Discharging: -20°C – 55°C |
| Storage Temperature | 0 – 25°C / 12 months |
| Waterproof Rating | IP52 |
| Protocol | CAN / RS485 |
| Cycle Life | ≥6000 times |
| Additional Features (optional) | |
| Heating Function | Activates when charging temperature is below 0°C (Automatically managed by BMS) |
| Certification / Compliance | |
| Certification / Compliance | IEC62619 / CE / UN38.3 |
Portable Energy Storage System

| Performance Parameters | |
|---|---|
| Nominal Capacity | 100Ah / 5120Wh (5.12V) |
| Battery Material | LiFePO₄ |
| Maximum Power Voltage Range | 60Vdc – 450Vdc |
| Rated Output Power | 6000W |
| AC Input Voltage | 220V |
| AC Output Voltage | 110V / 220V |
| Max. AC Output Current | 30A |
| Max. AC Output Power | 5500W |
| Maximum Conversion Efficiency (DC/AC) | 93% (Battery DC/AC) 97% (PV DC/AC) |
| Operating temperature | -10°C – 50°C |
| Output Waveform | Pure sine wave |
| Switch Time | <10ms |
| Dimensions (W×H×D) | 55 × 55 × 32cm |
| Cycle Life | ≥6000 times |
| Weight | 65 kg |