A gentle push for more convenient accessibility
Less Than 5 lbs of Push Force to Exit

Strength is Not the only Option, Exit Control Can Be Gentle
Without compromising any strength and durability of the Klacci 30 Series exit device, the accessible Rim Exit Device can be operated with 5 lbs of push force. Not only it meets the requirements of the 2010 ADA Standards and California Building Code 11B, the accessible rim exit devices are most suitable for accessibility demand from hospitals or health care centers.
The Exit Device for Anyone, Any Places
The accessible Rim Exit Device makes sure the exit can be operable with the least amount of force, while keeping the maximum strength. No one should be exempted from evacuation when it happens. Simply the choice of safety and security.
Features
The 30 Series Exit Devices are fabricated and blended with simplicity, strength, durability, aesthetics and installer-friendly innovations.

Simple cylinder built in add-on kit.
Special plastic inserts and rubber bumpers reduce noise and don’t fail under high or low temperatures. Impervious to petroleum lubricants.
Standard high-performance engineering plastic.
Trim designed for fast and easy installation.
Alloy steel latch and deadlatching blade add perceived value.
Integrated end cap reduced projection minimizes catch hazard and add stability to the push bar to move smoothly regardless of where the pressure is applied on push bar.
Push bar is smoothly surfaced. Light force applied to the push bar can release the latch. Accessible version is also available to meet the 2010 ADA Standards and Accessible Design to operate the device with 5 lbs of force.
Dogging can be done with an allen wrench, a small flat key or a flat blade screwdriver.
Flush end cap design.
Device Options
Details
Device Material
Finishes
![]() | ||||||
Color | ANSI/BHMA | US | D.E.G. | A | B.C.F.H. | |
![]() | Dark Oxidized Satin Bronze | 613 | 10B | Plastic | Plated | Anodized |
![]() | Satin Aluminum | 628 | US28 | Plastic | Plated | Anodized |
ANSI/ BHMA | Operation | Trim Option |
700 Series Trim | ||
01 | Exit Only | N |
02 | Dummy Pull Only | 702 |
03 | Night Latch, Key Retracts Latchbolt | N |
08 | Key Locks or Unlocks Latchbolt | 708 |
09 | Night Latch, Key Retracts Latchbolt | 709 |
14 | Lever / Knob Always Active, No Cylinder | HL3014 |
![]() | ![]() |
700 Series Trim | 30 Series Pull Trim |
![]() | ![]() | ![]() |
Dummy Trim | Passage Trim | Night Latch |
Lever or knob rigid for pull operation (For 02 function) | Lever or knob always active (For 14 function) | Key retracts latchbolt. Lever or knob is rigid (For 09 function) |
ANSI/BHMA | 02 | 08 | 09 | 14 | |
---|---|---|---|---|---|
![]() | ![]() | ![]() | ![]() | ![]() | |
Operation | Dummy Pull Only | Key Locks or Unlocks Latchbolt | Night Latch, Key Retracts Latchbolt | Lever Always Active, No Cylinder | Pull latch |
Trim No. | 702 | 708 | 709 | 714 | HL3014 |
Device No. | 31 | 31 | 31 | 31 | |
32 | 32 | 32 | 32 |
Cylinder Type
![]() | ![]() |
Standard | I/C |
Paddle Direction
The paddle direction can be installed upwards or downwards according to the users’ preferace.
![]() | ![]() |
Paddle Down | Paddle Up |
Lever / Grip Options
Lever Options | |
---|---|
![]() | ![]() |
D type (Standard) | Q type |
31 | 32 | ||
---|---|---|---|
Applications | Offices, schools, banks, assisted living facilities and other institutions or commercial buildings. | ||
Certification / Compliance | Panic devices UL/cUL listed for UL305 and ANSI/BHMA A156.3-2014 Grade 1 Panic Hardware. UL/cUL Fire rated for 3-hour Fire Exit Hardware, conforms to UL10C and UBC7-2. Also complies with NFPA 80 Fire doors and windows. Exit devices, levers, trims and pulls comply with American Disability Act (ADA) and NFPA 101 life safety code. | ||
Doors & Preparations | For new or retrofit installation into other manufacturers’ devices. For maximum door opening applications and listings for fire exit devices. | ||
– Mullion | with/without | ||
– Door Thickness | 1-3/4″ (45mm) ~ 2-1/4″ (57mm). Consult factory for other door thickness. | ||
– Door Wide | 3′ (914mm)(standard) ~ 4′ (1219mm). | ||
– Door High | (Panic) | 7′ (2134mm)(standard) ~ 10′ (3048mm). | |
(Fire) | 7′ (2134mm) (standard) ~ 8′ (2438mm). | 7′ (2134mm) (standard) ~ 10′ (3048mm). | |
– Device Centerline from Finished Floor | 39-5/8″ (1006mm). | ||
– Door Undercut | 1/4″ (6mm). | ||
Center Case | Universal center case, heavy wrought steel and sintered metal parts. Device functions are determined by adaptation with type of trim. | Heavy wrought steel assembly with top and bottom rod adjustors. | |
Top & Bottom Latch Case | 4-1/2″ × 2-1/8″ × 1-1/2″ (114mm × 54mm × 38mm). | ||
Center Case Latchbolt | Stainless Steel, deadlocking, 3/4″ (19mm) throw. | ||
Top Latchbolt | Stainless steel, Pullman type deadlocking, 5/8″ (16mm) throw. | ||
Bottom Latchbolt | Stainless steel, Pullman type deadlocking, independent action 5/8″ (16mm) throw. Round slide bolt optional. | ||
Fire Bolt | Available for door openings up to 8′ (2438mm) wide × 10′ (3048mm) high. Specify suffix “LBR”. | ||
Electrical Functions | Can be interfaced with building security systems: | ||
– AL Alarm Exit | √ | √ | |
– DE Delayed Egress Device | |||
– ELR Electric Latch Retraction | |||
– LM Latchbolt Monitoring | √ | √ | |
– RX Request to Exit | √ | √ | |
– SS Signal Switch | |||
– E Electric Mortise Lock | |||
Dogging | NOT available on fire exit hardware. Flat/hex key dogging standard. Dogging options available for LD, CD. | ||
Strikes | |||
– Panic | |||
— Top | 106Z (roller type) | ||
— Middle | 106Z (roller type) | ||
— Bottom | 227 | ||
– Fire | |||
— Top | 108 (roller type) | ||
— Middle | 108 (roller type) | ||
— Bottom | 227F | ||
Cylinders | NOT furnished standard, specify when required. | ||
Trim | The device and trim are sold separately, easy to mix and match. | ||
Handing | Device & trim non-handed. | ||
Fasteners | Machine screws and wood screws are furnished standard. | ||
Sex Bolts (SNB) | Required when used with wood, composite or non-reinforced hollow metal doors. |
![]() | ANSI Grade 1 | ![]() | Panic Application |
![]() | ANSI Grade 2 | ![]() | Fire Application |
![]() | ![]() | ![]() |
P/N. 106Z Rim Strike | P/N. 108 Rim Strike | P/N. 136 Rim Strike |
For RIM / SVR / 3PT top strike | For RIM / SVR / 3PT top strike For double door RIM / 3PT use with F170/F270 mullion | For double door RIM / SVR / CVR combination with coordinator |
![]() ![]() | ![]() ![]() ![]() |
Top Strike
![]() |
P/N. 215 Top Strike |
For flush transom SVR / 3PT |
Flat Bottom Strike
![]() | ![]() |
P/N. 225 Flat Bottom Strike | P/N. 226 Flat Bottom Strike |
Optional for SVR / CVR / 3PT round slide bolt | Optional for SVR / CVR / 3PT round slide bolt |
![]() ![]() ![]() | ![]() ![]() ![]() |
Bottom Strike
![]() | ![]() |
P/N. 227F Bottom Strike | P/N. 224 Bottom Strike |
Furnished standard for SVR / CVR / 3PT | Optional for SVR / 3PT |
![]() ![]() ![]() | ![]() ![]() ![]() |
![]() | ![]() |
P/N. 616819-010 | P/N. 616819-030 |
For 106 Rim Strike Two (2) pieces furnished standard | For 108 Rim Strike Two (2) pieces furnished standard |
Cylinders are not furnished standard with the device or trim, specify when required. Schlage® C keyway, 6-pin standard, available in 630 or 626 finish. Small format Interchangeable core combinated/uncombinated also available. Specify type and finish when ordering.
Cylinder Type | Applications | Cylinder | Cylinder Cam | |
---|---|---|---|---|
Mortise Cylinder![]() I/C | ![]() Standard | Dogging | Standard / I/C | Tailpiece Length 3-1/8″ (79.6mm) |
![]() | “A” keyway standard supplied. Specify 6 or 7 pin, combinated or uncombinated and finish 606 or 626 when ordering. Consult factory for other keyways. |

![]() | ![]() | ![]() |
LD | CD | HKD |
Less dogging | Cylinder Dogging | Flat/Hex Key Dogging |
Less dogging is available in all 30 Series panic exit devices. | Available for all models except for fire exit hardware. Cylinder dogging provides the ability to lock down the push bar with a key cylinder, allowing the door to be used in both push/pull mode. To order, specify “CD”. Requires the use of a 1-1/4″ (31.75mm) mortise cylinder (not furnished standard). |
A | B | ![]() Removable mullions are used with paired doors where a full width opening is only occasionally required. Doors are fitted with Rim exit devices and normally function as single doors. Available in 7′, 8′ or 10′ (2134mm, 2438mm or 3048mm) lengths. |
![]() | ![]() |
A | B | |
Model 170 / F170 Keyed Removable Mullion | Model 270 / F270 Non-Keyed Removable Mullion | |
Top and Bottom Fittings | Investment cast steel, furnished with steel anchors for floors. | |
Mullion | 2″ x 3″ (50.8mm x 76.2mm) steel. | |
Stock size | 8′ (2438mm) length standard, can be cut for opening less than 8′ (2438mm). 10′ (3048mm) length available upon request. | |
Finishes | 600, 689, 695. | |
UL Listed | Listed for 3-hour Fire Rated Exit Hardware. | |
Cylinder | Not furnished standard, keying is standard 1-1/8″ (28.5mm) mortise cylinder with cam. |
The head design of 170/F170

Provides a secure, quick and easy means of removal. The mullion can be installed and locked without using key.
Top Rod
Illustration | Device No. | Part No. | Rod Length | For Door Height |
---|---|---|---|---|
![]() | 32 | 368231501000 | 38-3/16″ (970mm) | 7′ |
368231501000 | 50-3/16″ (1275mm) | 8′ | ||
368231501000 Add 616823-040* | 50-3/16″ (1275mm) Add 24″ (609mm) | 10′ |
Bottom Rod
For push bar location at 39-5/8″ (1006mm) from finished floor.
Illustration | Device No. | Part No. | Rod Length |
---|---|---|---|
![]() | 32 | 368231401000 | 34-1/16″ (865mm) |
F30 Series Fire Exit Devices
Maximum Door Opening Applications and Listings
Exit Device | Door Material | Single Door | Double Door | |||
With 170 mullion | With 270 mullion | VR/VR Same Direction | VR/VR Double Egress | |||
F31 RIM | Metal | 3 Hours 4′ × 8′ | 3 Hours 8′ × 8′ | 3 Hours 8′ × 8′ | ||
F32 SVR | Metal | 3 Hours 4′ x 10′ | 3 Hours 8′ × 10′ | 3 Hours 8′ × 10′ | ||
F32 LBR | Metal | 3 Hours 4′ x 10′ | 3 Hours 8′ × 10′ | 3 Hours 8′ × 10′ |
Notes:

Rim Exit Device / Vertical Rod Exit Devices
Panic | RIM | 31 | Up to 4′ × 10′ Door Size |
SVR | 32 | ||
Fire (3 Hours) | RIM | F32 | Up to 4′ × 8′ Door Size |
SVR | F32 | Up to 4′ × 10′ Door Size |

Two Surface Vertical Rod Devices
Panic | SVR × SVR | 32 × 32 | Up to 8′ × 10′ Door Size |
Fire (3 Hours) | SVR × SVR | F32 × F32 |

Two Surface Vertical Rod Devices Less Bottom Rod
Panic | SVR × SVR | 32LBR × 32LBR | Up to 8′ × 10′ Door Size |
Fire (3 Hours) | SVR × SVR | F32LBR × F32LBR |

Two Rim Exit Devices with Removable Mullion
Panic | RIM × RIM | 31 × 31 | Up to 8′ × 10′ Door Size |
Fire (3 Hours) | RIM × RIM | F31 × F31 | Up to 8′ × 8′ Door Size |

Surface Vertical Rod Devices Less Bottom Rod
Panic | SVR × SVR | 32LBR × 32LBR | Up to 8′ × 10′ Door Size |
Fire (3 Hours) | SVR × SVR | F32LBR × F32LBR |

Two Surface Vertical Rod Devices
Panic | SVR × SVR | 32 × 32 | Up to 8′ × 10′ Door Size |
Fire (3 Hours) | SVR × SVR | F32 × F32 |

One Rim Exit Device × One Vertical Rod Device
Panic | RIM × SVR | 31 × 32 | Up to 8′ × 10′ Door Size |
Fire (3 Hours) | RIM × SVR | F31 × F32 |