Automatic Flush Bolts. Simple.

Inactive door locks automatically when the active door is closed; Inactive
door unlocks automatically when the active door is opened.


Specifications
Certification/Compliance | • ANSI/BHMA A156.3 Grade 1.
• Conforms to ANSI/BHMA 156.3 type 25. |
Features | • The override spring prevents damage to the doors or bolts should the bolt head fail to align with top and bottom strike.
• The Auxiliary Fire Fuse assembly keeps the door aligned during a fire. In case of fire, the bolt extends from the fire fuse to keep the inactive door in the locked position.
• Patented floating cams for less than 5 lbs. of closing force required from the active door to extend both top and bottom bolts.
• Non-handed. |
Top and Bottom Bolts | • Bolts can be vertically adjusted up to 1″ for floor variance or frame conditions.
• 3/4″ bolt throw and 3/4″ backset. |
Strike | • 95-2701 Strike standard.
• 95-2705 or 95-2706 dust proof strike available. |
Standard Rod Length | • 12″ standard rod length measured from the center of the flush bolt body to the bolt tip. Optional 18″,24″,36″ and 48″ rod lengths available for top bolt only on non-fire rated openings. |
Doors & Preparations | • Fits standard ANSI/BHMA A156.115 (A115.4). |
Finishes | • 605, 606, 611, 612, 613, 625, 626, 630. |
Ordering information | • FB9510R, FB9520R Model (without bottom bolt) with Auxiliary Fire Bolt includes a retrofit plate kit NO.95-2801 to cover existing bottom bolt prep. |
Self-Latching Flush Bolts. Sophisticate.

Opening the active door + Manually unlatching the top bolt
= inactive door is accessible; Closing the inactive and active
door leaf in sequence = inactive door is secured.


Specifications
Certification/Compliance | • ANSI/BHMA A156.16 Grade 1.
• Conforms to ANSI/BHMA 156.16 type 27. |
Features | • The override spring prevents damage to the doors or bolts should the bolt head fail to align with top and bottom strike.
• The Auxiliary Fire Fuse assembly keeps the door aligned during a fire. In case of fire, the bolt extends from the fire fuse to keep the inactive door in the locked position.
• Patented floating cams for less than 5 lbs. of closing force required from the active door to extend both top and bottom bolts.
• Non-handed. |
Top and Bottom Bolts | • Bolts can be vertically adjusted up to 1″ for floor variance or frame conditions.
• 3/4″ bolt throw and 3/4″ backset. |
Strike | • 95-2702 Strike standard.
• 95-2705 or 95-2706 dust proof strike available. |
Standard Rod Length | • 12″ standard rod length measured from the center of the flush bolt body to the bolt tip. Optional 18″,24″,36″ and 48″ rod lengths available for top bolt only on non-fire rated openings. |
Doors & Preparations | • Fits standard ANSI/BHMA A156.115 (A115.4). |
Finishes | • 605, 606, 611, 612, 613, 625, 626, 630. |
Ordering information | • FB9510R, FB9520R Model (without bottom bolt) with Auxiliary Fire Bolt includes a retrofit plate kit NO.95-2801 to cover existing bottom bolt prep. |
Manual Flush Bolts. Controls.

Switching the lever/snib upward to unlock, downward to lock; You
now have access control of the inactive door in your fingers.


Specifications
Certification/Compliance | • ANSI/BHMA A156.16 Grade 1.
• Conforms to ANSI/BHMA 156.16 , L04251, L04261, L0429. |
Features | • Ease of installation.
• Non-handed. |
Standard Rod Length | • 12″ standard rod length measured from the center of the flush bolt body to the bolt tip. Optional 18″,24″,36″ and 48″ rod lengths available for top bolt only on non-fire rated openings. |
Doors & Preparations | • Fits standard ANSI/BHMA A156.115 (A115.4).
• Fits standard ANSI/BHMA A156.115W (A115.W5). |
Finishes | • 605, 606, 611, 612, 613, 625, 626, 630. |
| | FB9530* | FB9531* | FB95410 | FB95411 |
Top and Bottom Bolts | Bolt throw | 3/4″ | 3/4″ | 1″ | 3/4″ |
Backset | 3/4″ | 3/4″ | 1/2″ | 1/2″ |
Bolt tip | 1/2″ | 1/2″ | 1/2″ | 5/16″ |
Strike | Standard. | 95-2708 | 95-2708 | 95-2707 | 95-2709 |
Optional | 95-2705 or 95-2706 | 95-2705 or 95-2706 | | |